Extraits du catalogue

Analyseur ProCeas® HF-1

ProCeasc No sample pre-treatment No Heated Lines1 Multi-Components Pre-Calibrated No interference No Drift ' EASE-OF-I The ProCeas® allows digital (Ethernet, RS485, RS232, ModBus), analog and TDR I/O’s. ' ROBUSTNESS The ProCeas® contains no optical moving parts and was designed and built strictly for industrial and on-board mobile applications. ' LOW MAINTENANCE High MTBF. In addition to containing no moving optical components, the IR sources (telecom type laser) are characterized by MTBF’s of 5 years. ' CLEAN LINES / FILTERS The low pressure sampling system enables low flow rates (3-9 L/h) without degrading response time. Accumulation of contaminants Unes and filters is greatly reduced. ' SAFE ATEX compliant configuration available. ProCeas® HF Trace analyzer Low level HF Detection in Ambient Air O The ProCeas® HF is a complété pre-calibrated laser infrared spectrometer for measurement of louu level HF ambient air xThe ProCeas® HF uses the patented OFCEAS (WO 03031949) IR Laser technologyfor enhanced specificity, selectivity, accuracy and stability (no instrumental response drift.) ' The ProCeas® HF uses a patented low-pressure sampling system (WO 2010058107) enabling low-cost installation thank to non-heated Unes1 and reduced maintenance. The ProCeas® HF is a complete, reliable, robust, low-cost and easy-to-use solution for the low level HF analysis ambient air. ProCeas® Advantages & Benefits ' DIRECT MEASUREMENT No sample pre-treatment. OFCEAS technology associated with low pressure sam-pling enables direct measurement. The low pressure in the sampiing system removes any risk for chemicais adsorption/desorption and condensation in the line. ' NO INTERFERENCE OFCEAS technology associated with low pressure sampling provides exceptional selectivity, enabling si-multaneous multi-component measurement without interferences, regardless of the matrix. ' NO RE-ZERO; NO DRIFT The zero information is contained in the signal, enabling automated and intrinsic re-zero of the analyzer. ' EASE-OF-USE The ProCeas® is pre-calibrated for your application. Ini-tially packaged in a standard 19”rack, it includes a touch screen interface and on-board PC for local / remote control and real time display / recording of results. Requires ambient temperature > 10°C and H2O < 65 % vol

 Ouvrir le catalogue en page 1
Analyseur ProCeas® HF-2

Flow Rate : H2O(g) < 65% vol. - Standard H2O(g) > 65% vol. – Study Required 1 atm. ± 100 mbar @ sampling point Sampling Line : Ambient Temp. > 10°C et H2O <65% vol. > Simple polytube (no heating) Ambient Temp. < 10°C et H2O >65% vol. > 80°C heated line DIMENSIONS Size : Ethernet Protocol; RS 485 RS 232; ModBus. Analog I/O; TDR I/O. Other I/O’s on request ANALYTICAL SPÉCIFICATIONS Rangea Gas HF Response Time Zero Drift : Wall mounted ATEX compliant integration adjustable range on request b limit of detection 3 Sigma SPECTRA (Examples) - 200 equidistant data points over 0,2 nm 5.7” diagonal color...

 Ouvrir le catalogue en page 2

Tous les catalogues et fiches techniques (PDF) AP2E

Catalogues archivés

  1. ProCeas H2S

    2  Pages

  2. proceas_nh3

    2  Pages

  3. Epsilon 5000

    2  Pages

* Les prix s'entendent hors taxe, hors frais de livraison, hors droits de douane, et ne comprennent pas l'ensemble des coûts supplémentaires liés aux options d'installation ou de mise en service. Les prix sont donnés à titre indicatif et peuvent évoluer en fonction des pays, des cours des matières premières et des taux de change.