BOOSTER REGULATOR Order example: PORT THREAD • Increase factory air pressure by up to twice as much. • Air-only opération requires no power supply, reduces heat génération, and allows easy installation. • If the outlet capacity is undersized, plusation may occur. • Make sure to install a mist separator at the inlet side of the booster regulator. • The booster regulator has a sliding part inside, and it générâtes dust. Also, install a cleaning device such as an air filter or a mist separator on the outlet side as necessary. • Provide a dedicated pipe to release the exhaust air from each booster regulator. If exhaust air is converged into a pipe, the back pressure that is created could cause improper • Depending on the necessity, install a silencer on the exhaust port of the booster regulator to reduce the exhaustion sound. • Allow the sufficient space for maintenance and inspection.
Ouvrir le catalogue en page 1BOOSTER REGULATOR Flow Characteristics Charge Characteristics Operating pressure: • When only one side of the cylinder is used for work, booster regulators can be installed only on the Unes that require them to reduce the overall air consumption volume.
Ouvrir le catalogue en page 2BOOSTER REGULATOR O Warning concerning abnormal outlet pressure • If there is a likelihood of causing an outlet pressure drop due to unforeseen circumstances such as equlpment malfunction, thus leadlng to a major problem, take safety measures on the System • Because the outlet pressure could exceed its set range if there is a large fluctuation in the inlet pressure, leading to unexpected accidents, take safety measures against abnormal pressures. • Operate the equipment within its maximum operating pressure 0 Residual pressure measures • Connect a 3-port valve to the OUT side of the booster regulator...
Ouvrir le catalogue en page 3BOOSTER REGULATOR • If air is supplied to the product in the shipped state, the air will be Set the pressure by quickly pulling up on the governor handle, releasing the lock, and rotating the handle in the direction of the • There is an upper and lower limit for the handle rotation. If over- rotating the handle even after reaching to the limit, the internai parts may be damaged. If the handle suddenly feels heavy while being turned, stop turning the handle. • Once the setting is completed, push the handle down and lock it. • To decrease the outlet pressure, after the pressure has been set, rotate...
Ouvrir le catalogue en page 43 Pages
11 Pages
13 Pages
15 Pages
10 Pages
6 Pages
3 Pages
40 Pages
40 Pages
3 Pages
8 Pages
8 Pages
1 Page
3 Pages
5 Pages
2 Pages
3 Pages
3 Pages
1 Page
17 Pages
5 Pages
18 Pages
8 Pages
8 Pages
4 Pages
3 Pages
4 Pages
2 Pages
4 Pages
14 Pages
18 Pages
13 Pages
22 Pages
20 Pages
5 Pages
9 Pages
4 Pages
4 Pages
5 Pages
15 Pages
11 Pages
22 Pages
11 Pages
11 Pages
15 Pages
9 Pages
2 Pages
13 Pages
5 Pages
5 Pages
5 Pages
10 Pages
12 Pages
28 Pages
12 Pages
4 Pages
36 Pages
13 Pages
5 Pages
2 Pages
4 Pages
16 Pages
4 Pages
7 Pages