video corpo

Stream - La technologie de compresseur à pistons semi-hermétique de pointe
13Pages

{{requestButtons}}

Extraits du catalogue

Stream - La technologie de compresseur  à pistons semi-hermétique de pointe - 1

Stream - The State Of The Art Semi-Hermetic Piston Technology

Ouvrir le catalogue en page 1
Stream - La technologie de compresseur  à pistons semi-hermétique de pointe - 2

Production Launch of Stream Pioneering Technologies And Global Expertise Challenging Applications Require Superior Technologies For more than 80 years we have been introducing pioneering technologies to the market, from the first semi hermetic and hermetic compressor in the 1940s and 1950s, to the brand new and high efficiency semi hermetic “Stream “and scroll compressors of nowadays. With our strong investment in R&D and in product engineering combined with technically superior Staying abreast of the market´s challenges Emerson continues to develop and improve its compressor technologies:...

Ouvrir le catalogue en page 2
Stream - La technologie de compresseur  à pistons semi-hermétique de pointe - 3

Stream Technology And Its 5 Key Benefits MULTI REFRIGERANTS CORE SENSE EFFICIENCY Diagnostics CoreSense™ Diagnostics technology helps your refrigeration equipment last longer. This technology offers advanced compressor protection, diagnostics, communication and power consumption measurement. Efficiency Its unique valve technology makes Stream 10% more efficient than any other compressor and therefore helps you reduce the carbon footprint and running cost of your installation. EFFICIENCY MULTI REFRIGERANTS CORE SENSE MULTI REFRIGERANTS EFFICIENCY CORE SENSE Multi Refrigerant Its unique valve...

Ouvrir le catalogue en page 3
Stream - La technologie de compresseur  à pistons semi-hermétique de pointe - 4

MULTI REFRIGERANTS CORE SENSE Stream - A Broad Family For The Perfect Application Fit Stream For HFC Refrigerants Our Stream range provides best in class performance for today’s commonly used HFCs and uprising low GWP refrigerants. The result? Significantly smaller cost of operation and reduced environmental impact compared to competing products. The range comprises 4 and 6 cylinder models that are qualified for inverter applications as well as 4 and 6 cylinder digital models for continuous cooling capacity modulation. The compressors can be fitted with a dedicated sound shell for sound...

Ouvrir le catalogue en page 4
Stream - La technologie de compresseur  à pistons semi-hermétique de pointe - 5

MULTI REFRIGERANTS CORE SENSE Intelligent CoreSense™ Diagnostics Add Value To Your System What It Means To You Advanced Motor Protection Using proprietary algorithms, CoreSense goes beyond conventional basic motor protection. It protects the compressor from severe damagecausing failures like locked rotor, single phasing and voltage imbalances. Furthermore CoreSense provides discharge temperature protection. CoreSense Architecture CoreSense Diagnostics Control Module CoreSense Diagnostics Features Discharge Temperature Sensor It enables remote reset capability and remote monitoring of the...

Ouvrir le catalogue en page 5
Stream - La technologie de compresseur  à pistons semi-hermétique de pointe - 6

Environmental impact and energy consumption is at the center of every discussion relating to sustainable refrigeration. Retailers face important challenges as they strive to find the right balance between ecological and economical aspects. Therefore energy efficiency is always under scrutiny as it impacts both the carbon footprint and the costs relative to an installation. Conventional Compressor With “Reed” Valve Technology Stream Compressor With Discus™ Valve Technology By leveraging and improving the Discus valve technology, the new Stream features a series of design characteristics that...

Ouvrir le catalogue en page 6
Stream - La technologie de compresseur  à pistons semi-hermétique de pointe - 7

MULTI REFRIGERANTS CORE SENSE Multi Refrigerant One Compressor - Multiple Applications At Best Efficiency SOUND Today’s most commonly used refrigerant is R404A. Improving system architectures, changing compressor technology or moving to a refrigerant with a lower Global Warming Potential (GWP) can significantly improve the carbon footprint of an installation. Efficiency Comparison Moving from R404A to R134a is one of many ways to reduce the GWP (from 3922 to 1430). While this requires a compressor of bigger displacement for the same capacity, the GWP is reduced by 64% and the system’s...

Ouvrir le catalogue en page 7
Stream - La technologie de compresseur  à pistons semi-hermétique de pointe - 8

Modulation SOUND One Compressor - Two Modulation Options There is a common goal shared by many in refrigeration: preserve and display food at safe temperatures and reasonable operating cost. Varying the capacity available to meet the load is the most significant way to achieve this objective. This ability leads to a more stable temperature in the refrigerated areas and does so at favorable power consumption since producing excess capacity is avoided. What It Means To You All Stream compressors are released for applications using inverter technology. In addition, and in an effort to give...

Ouvrir le catalogue en page 8
Stream - La technologie de compresseur  à pistons semi-hermétique de pointe - 9

Modulation SOUND Our Digital Technology - Your Benefits Apart from these benefits digital modulation offers significiant additional advantages as described to the right. Features & Benefits êê o specific precautions are necessary with respect N to oil return as Stream Digital runs at constant speed just like a standard compressor Noise Emissions - A Serious Concern Cycle Time The compressor capacity is controlled by modulating the solenoid valve input over time. Example 1 : •  Cycle time: 20 sec •  Valve active/open: 10 sec •  Valve inactive/closed: 10 sec •  Resulting capacity: 50% The...

Ouvrir le catalogue en page 9
Stream - La technologie de compresseur  à pistons semi-hermétique de pointe - 10

Designed For Durability And Best-In-Class Performance Technical Specifications The Stream line of 4 cylinder R744 compressors is the ideal solution for R744 medium temperature cascade and booster systems. It is characterised by a design pressure of 135 bar. Refrigerant flow and heat transfer have been optimized for best performance. All compressors are equipped with CoreSenseTM technology and offer the possibility to diagnose system related problems faster or even before they occur. Operating Envelopes With R744 Evaporating Temperature°C Technical Overview Model Features & Benefits Designed...

Ouvrir le catalogue en page 10
Stream - La technologie de compresseur  à pistons semi-hermétique de pointe - 11

Technical Specifications Technical Specifications Operating Envelopes With R404A Operating Envelopes With R404A (100% Capacity Modulation) Large Motor 60 50 Large Motor Small Motor Evaporating Temperature°C Evaporating Temperature°C Small Motor Evaporating Temperature°C Evaporating Temperature°C For envelopes with R134a, R407F, R407A/C, R22 refer to Selection Software. For envelopes with R134a, R407F, R407A/C, R22 refer to Selection Software. Technical Overview Technical Overview (100% Capacity Modulation) Evaporating -10°C, condensing 45°C, suction gas temperature 20°C, subcooling 0K...

Ouvrir le catalogue en page 11

Tous les catalogues et fiches techniques (PDF) Emerson Commercial & Residential Solutions

  1. 1E78-151

    2 Pages

  2. TLE series

    2 Pages

  3. ZZ series

    2 Pages

  4. 204CD

    2 Pages

  5. 214CB

    2 Pages

  6. 222CB

    2 Pages

  7. 314UB

    2 Pages

  8. 50RB

    2 Pages

  9. 100RB

    2 Pages

  10. 200RB

    3 Pages

  11. 200RD

    2 Pages

  12. 240RA

    2 Pages

  13. 500RB

    2 Pages

  14. 540RA

    2 Pages

  15. NXT Series

    2 Pages

  16. TFE R-410A

    1 Pages

  17. TI Series

    1 Pages

  18. A Series

    3 Pages

  19. HF Series

    2 Pages

  20. BA/BN Series

    3 Pages

  21. EX Brochure

    4 Pages

Catalogues archivés

  1. Coils

    3 Pages

  2. Solenoid Valve

    25 Pages