Modular online UPS 200-600KW CNM330
2Pages

{{requestButtons}}

Extraits du catalogue

Modular online UPS 200-600KW CNM330 - 1

Constant Electric Power Constant Electric Power CNM330 Series Technical Specifications CNM330 Series Technical Specifications CNM330 200-600KVA Module capacity (VA/W) Max. module number Battery Voltage Optional Voltage: 384Vdc~480Vdc (30~40 pcs, 40 pcs define, 36 and 50 pcs no power derating; 32~34 pcs output power factor Module charge current (A) max. Phase 3 Phase 4 Wires and Ground Transfer Time Rated Voltage Voltage Range Utility to Battery : 0ms; Utility to bypass: 0ms ◆ At 40°C: The UPS works at ful l load when the voltage is 323–485Vac and is derated load when the voltage is 323–138Vac ◆ At 30°C: The UPS works at ful l load when the voltage is 305–485Vac and is derated load when the voltage is 305–138Vac Frequency Range Power Factor Current THDi Bypass Voltage Range Flexible Modular Parallel Redundancy UPS 200-600KVA Protection Short Circuit Overheat Hold Whole System Line Mode: Switch to Bypass; Backup Mode: Shut down UPS immediately Upon Power On and Software Control Shut down UPS immediately Advanced Battery Management Noise Suppression Min. voltage:-45 %( optional -10%, -20%,-30%) Communication Interface Frequency protection range: ±10% CAN, RS485, FE, LBS, Parallel, Relay card, SNMP card(optional) Output 3 Phase 4 Wires and Ground Rated Voltage Power Factor Frequency Battery Mode Crest factor ≤2% with l inear load ≤4% with non l inear load Storage Temperature Humidity Voltage Regulation Utility Mode Operating Temperature Inverter overload capability: ◆ 105% < load ≤ 110%: transfer to bypass mode after 60 min ◆ 110% < load ≤ 125%: transfer to bypass mode after 60 min ◆ 125% < load ≤ 150%: transfer to bypass mode after 60 min Bypass overload capability: ◆ Temperature ≤ 30°C, load ≤ 135%: run for a long time ◆ Temperature ≤ 40°C, load ≤ 125%: run for a long time ◆ 1000% load: run for 100 ms STANDARD: Conform to GB/IEC regulation: EMC: GB7260.2/IEC62040-2 -GB/17626.2~5/IEC61000-4-2~5 SAFETY: GB4943 Note: Product specifications are subject to change without further notice. Audible & Visual Line Failure, Battery Low, Overload, System Fault UPS Fault, Alarm and normal GREEN ENERGY SAVING ENVIRONMENTAL PROTECTION Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage, parameter set, history record… Other Standard cabinet Dimensions (W*D*H) Full cabinet Dimensions (W*D*H)(mm) Module Dimensions(W*D*H) (mm) Cabinet Weight (Kg) Safety Conformance STANDARD: Conform to GB/IEC regulation: EMC: GB7260.2/IEC62040-2 -GB/17626.2~5/IEC61000-4-2~5 SAFETY: GB4943 Note: Pro

Ouvrir le catalogue en page 1
Modular online UPS 200-600KW CNM330 - 2

CNM330 Series Flexible Modular Parallel Redundancy UPS 200-600KVA Key features & Function: ■ N+X parallel redundancy Notice: (1)LCD panel : Display UPS data and status This series UPS adopts N+X parallel redundancy design, user can set different (2)power cabinet : Assembly power module (3)Power distribution cabinet : Assembly control unit, bypass module and switch redundancy according to the importance of the load. While the redundancy modules are set more than two, the availability of UPS system will achieve 99.999%, which may satisfy the required reliability of the critical load...

Ouvrir le catalogue en page 2

Tous les catalogues et fiches techniques (PDF) Shenzhen Consnant Technology Co.

  1. APF&SVG

    1 Pages

  2. Home ESS

    1 Pages

  3. APF/SVG

    1 Pages

  4. APF(SVG)

    10 Pages

  5. Outdoor UPS

    1 Pages

  6. ESS

    1 Pages

  7. Moduar UPS

    1 Pages