OPERATING INSTRUCTIONS SICK Sensor Intelligence.
Ouvrir le catalogue en page 1OPERATING INSTRUCTIONS
Ouvrir le catalogue en page 2Described product WTB16 - Bluetooth® Manufacturer SICK AG Erwin-Sick-Str. 1 79183 Waldkirch Germany Legal information This work is protected by copyright. Any rights derived from the copyright shall be reserved for SICK AG. Reproduction of this document or parts of this document is only permissible within the limits of the legal determination of Copyright Law. Any modification, abridgment or translation of this document is prohibited without the express writ-ten permission of SICK AG. The trademarks stated in this document are the property of their respective owner. © SICK AG. All rights...
Ouvrir le catalogue en page 38022691 | SICK Subject to change without notice
Ouvrir le catalogue en page 4Safety information General safety notes Read the operating instructions before commissioning. Connection, mounting, and configuration may only be performed by trained specialists. ■ Not a safety component in accordance with the EU Machinery Directive. When commissioning, protect the device from moisture and contamination. These operating instructions contain information required during the life cycle of the sensor. Notes on UL approval The device must be supplied by a Class 2 source of supply. UL Environmental Rating: Enclosure type 1 Intended use The WTB16 Bluetooth is an opto-electronic...
Ouvrir le catalogue en page 5@ Center of optical axis, receiver © LED indicator green: Supply voltage active 7 LED indicator yellow: Status of received light beam © Press-turn element: Adjusting the sensing range ® BluePilot blue: Sensing range dis- Mount the sensor using a suitable mounting bracket (see the SICK range of acces-sories). Note the sensor's maximum permissible tightening torque of < 1,3 Nm. Note the preferred direction of the object relative to the sensor, cf. figure 1 and 2. Electrical installation The sensors must be connected in a voltage-free state (UV = 0 V). The following information...
Ouvrir le catalogue en page 6Bluetooth® is switched on for initial commissioning. You can get SOPASair in the Google PlayStore (Android) and in the App Store (iOS). Operating system requirements: Android version 6.0, most current version of iOS. 8022691 | SICK to change without notice
Ouvrir le catalogue en page 7Alignment WTB16P Bluetooth®: Align sensor on object. Select the position so that the red emitted light beam hits the center of the object. You must ensure that the optical opening (front screen) of the sensor is completely clear [see figure 3, see figure 4]. WTB16I Bluetooth®: Align sensor on object. Select the position so that the infrared light (not visible) hits the center of the object. The correct alignment can only be detected via the LED indicators. see figure 3, figure 4 , see table 1, see table 2. You must ensure that the optical opening (front screen) of the sensor is completely...
Ouvrir le catalogue en page 8Example: Sensing range on black, 6%, A = Detection distance (depending on object remission) BluePilot; Sensing range indicator (blue LED) Teach-Turn adjustment A = Detection distance (depending on object remission) BluePilot; Sensing range indicator (blue LED) Teach-Turn adjustment Sensing range setting Subject 8022691 I SICK to change without notice
Ouvrir le catalogue en page 9COMMISSIONING 6 WTB16x-xxxxxx2xAxx with press-turn element: The sensing range is adjusted by pressing the teach-in button (approx. 1-3 sec.). Depending on the requirements, the potentiometer can be used for fine-tuning (without pressing the teach-in button). Clockwise rotation: sensing range increased. Counterclockwise rotation: sensing range reduced. The sensing range can also be adjusted using just the potentiometer. We recommend placing the object within the sensing range, see figure 8 for an example. Once the sens‐ ing range has been adjusted, the object is removed from the path of the...
Ouvrir le catalogue en page 106 COMMISSIONING WTB16x-xxxxxx1xAxx with potentiometer: The sensing range is adjusted with the potentiometer. Clockwise rotation: sensing range increased. Counterclockwise rotation: sensing range reduced. We recommend placing the object within the sensing range, see figure 9 for an exam‐ ple. Once the sensing range has been adjusted, the object is removed from the path of the beam, which causes the background to be suppressed and the switching output to change (see table 1, table 2). Figure 9: WTB16x-xxxxxx1xAxx, adjusting the sensing range with potentiometer 8022691 | SICK Subject to change...
Ouvrir le catalogue en page 11COMMISSIONING 6 WTB16x-xxxxxx3xAxx with teach-in button: The sensing range is adjusted by pressing the teach-in button (approx. 1-3 sec.). We recommend placing the object within the sensing range, see figure 10 for an example. Once the sensing range has been adjusted, the object is removed from the path of the beam, which causes the background to be suppressed and the switching output to change (see table 1, table 2). Figure 10: WTB16x-xxxxxx3xAxx, adjusting the sensing range with teach-in button 8022691 | SICK Subject to change without notice
Ouvrir le catalogue en page 12Process data structure (Version 1.1) 8022691 | SICK to change without notice
Ouvrir le catalogue en page 13This device complies with Part 15 of the FCC Rules and with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any inter-ference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d'industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit...
Ouvrir le catalogue en page 14Changes or modifications made to this equipment not expressly approved by SICK AG may void the FCC authorization to operate this equipment. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide rea-sonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio fre-quency energy and, if not installed and used in accordance with the instruction manual, may cause harmful...
Ouvrir le catalogue en page 1517 Pages
12 Pages
15 Pages
4 Pages
6 Pages
5 Pages
4 Pages
20 Pages
110 Pages
48 Pages
24 Pages
124 Pages
5 Pages
56 Pages
12 Pages
134 Pages
2 Pages
20 Pages
48 Pages
29 Pages
8 Pages
37 Pages
32 Pages
12 Pages
20 Pages
20 Pages
8 Pages
20 Pages
84 Pages
44 Pages
2 Pages
8 Pages
20 Pages
92 Pages
4 Pages
12 Pages
8 Pages
171 Pages
228 Pages
2 Pages
16 Pages
56 Pages
486 Pages
164 Pages
170 Pages
1054 Pages
174 Pages
388 Pages
404 Pages
124 Pages
308 Pages
5 Pages
5 Pages
20 Pages
5 Pages
5 Pages
5 Pages
6 Pages
5 Pages
4 Pages
2 Pages
4 Pages
8 Pages
7 Pages
100 Pages
8 Pages